Solvents and additives in HPLC: when the invisible causes problems

In this post, we discuss why mobile phase degassing is essential for achieving stable and accurate results in HPLC. We analyze the effects of dissolved gases on chromatographic analysis—such as baseline noise, retention variations, or bubbles in the system—and explain the most common techniques for removing them, from online degassing to the use of helium or sonication. We also include practical tips on solvent storage and best practices to avoid errors.


In liquid chromatography, there are details that aren't visible… but they make a difference. One of the most common (and often underestimated) is the quality of the solvents and additives used in the mobile phase. Even if they appear correct at first glance, if they lack the necessary purity, they can completely compromise your analysis.

Why does purity matter so much?

Because pollutants—even in trace amounts—can cause:

    • Unstable baselines

    • Unwanted peaks (the famous ghost peaks )

    • Low sensitivity in detection

    • Damage to the spine or the system

Each analytical method has its own requirements. In gradient applications, for example, the solvents must be of a specific grade to ensure reproducible results. And if you're working with mass spectrometry, using LC-MS solvents isn't optional: it's essential.

Water: Is it truly pure?

The water you use in your analyses must be more than just "clean." Ideally, it should be ultrapure and tailored to your needs (HPLC or LC-MS grade). Specialized purification systems ensure it is free of inorganic and organic contaminants, something a simple deionizer cannot guarantee. Keep in mind: often, water is the biggest source of noise in the system, and you may not even realize it.

Buffers and solutions: the latest and best filtered is always better

Aged or improperly stored buffers also pose a risk. In addition to degrading over time, they can serve as a breeding ground for microorganisms. To avoid this:

    • Prepare the solutions just before the analysis.

    • Always filter: 0.22 μm if using UHPLC, 0.45 μm for conventional HPLC.

    • Adding a small percentage of organic solvent or preservatives such as sodium azide can make a difference.

 

 

Human errors: as common as they are avoidable

Poorly sealed caps, bottles left open on the bench for hours, returning solvents to their original containers, or using expired reagents… These are small things, but their consequences can be significant. And the worst part: often you won't know where the problem is coming from until it's too late.

 

Take advantage of Carlo Erba's special promotion on solvents for liquid chromatography. Click here.


Artículos recomendados

See all
V Interdisciplinary Congress on Human Genetics (AEGH)
V Interdisciplinary Congress on Human Genetics (AEGH)
The Proquinorte team will be present at the Granada Conference Centre for the 5th Interdisciplinary Congress on Human Genetics (AEGH), a key meeting point for professionals in the clinical, research and diagnostic fields.
Unambiguous HLA typing: why full-length typing is a game-changer
Unambiguous HLA typing: why full-length typing is a game-changer
HLA typing is a critical component in multiple areas of modern medicine: organ and bone marrow transplantation, clinical immunology, pharmacogenomics, and personalized medicine. However, for years, laboratories have faced a significant limitation: ambiguity in the results, especially when using short-read NGS-based methodologies.
PFAS: what they are and how to detect the “forever chemicals”
PFAS: what they are and how to detect the “forever chemicals”
PFAS (per- and polyfluoroalkyl substances) are a family of more than 3,000 synthetic compounds that have been used since the 1940s in sectors as diverse as the textile, food, automotive, and chemical industries. Among the best known are PFOA, PFOS, and GenX.